· If during the course of any job, any pipe is found that is not on the locate sheet and is in conflict with your work, please call our emergency number (1-877-969-0999), and one of our Union Gas representatives will respond to determine if that plant is in fact live or dead.

· Please note that our Enbridge Gas representative will respond to the live or dead call within 1-4 hours, so please plan your work accordingly.

ENWIN Utilities

Hydro Engineering: No Objection to rezoning only.

Water Engineering: Water Engineering has no objections to the rezoning.

Engineering Department Right-of-Way

The site may be serviced by a 450mm x 600mm brick combined sewer along the Pierre Avenue right-of-way. If possible existing connections should be utilized. Any redundant connections shall be abandoned in accordance with the City of Windsor Engineering Best Practice B.P 1.3.3. The applicant will be required to submit site servicing drawings and storm detention calculations restricting storm water runoff to pre-development levels.

Schedule X of the Official Plan classifies Pierre Avenue as a Local Road, requiring a right-of-way width of 20.1m. The current right-of-way is sufficient therefore a conveyance is not required. Driveways are to be constructed as per AS-221 or AS-222, complete with straight flares and no raised curbs within the right-of-way. The owner will also be required to contribute to the City of Windsor’s alley maintenance fund in the amount of $1000.00.

In summary we have no objection to the proposed rezoning, subject to the following requirements (Requirements can be enforced during site plan control):

Site Plan Control Agreement – The applicant enters into an agreement with the City of Windsor for all requirements under the General Provisions of the Site Plan Control Agreement for the Engineering Department.

Alley Contribution – The owner agrees, prior to the issuance of a Building Permit, to contribute the sum of $1000.00 payable to the City of Windsor and deposited in the General Fund intended for the upkeep of alleys within the City of Windsor.

Existing Sewers and Connections - The owner further agrees, at its entire expense and to the satisfaction of the City Engineer:

  1. To undertake a video inspection of the mainline sewers that will be used by the subject property and all connections to the mainline sewers that service the subject property.

  2. Any redundant connections will be abandoned according to the City of Windsor Engineering Best Practice B.P.1.3.3.

  3. Any new connections to combined sewers will follow City of Windsor Engineering Best Practice B.P.1.1.1.